| TM 11-5820-695-35
connected through R32 to pin 4 of threshold detector
R25, R27 and R28 and the level is adjusted (R27) to
slightly less than 700 mv. The output signal at U18-2 is
U1B. The signal level at UlB.4 is normally less than 700
mv and for fault status it is greater than 700 mv. A
normally high (open circuit) and +28 vdc through R30
and R33 reverse biases CR7. For fault status the signal
reference signal at U1B-5 is derived from +28 vdc
at U18B-2 is ground and CR7 is forward biased.
through
Change 6 2-139
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |