2-72. RELAY K3001 REPLACEMENT.
MATERIALS/PARTS: Relay, K3001 (P/N SMD413526)
PRELIMINARY PROCEDURE: Remove case (para 2-39).
REMOVAL
1. Using screwdriver, loosen captive screw (1).
2. Remove retaining plate (2).
3. Pull relay (3) straight up from socket (4).
INSTALLATION
1. Position relay (3) in socket (4) and push into place.
2. Position retaining plate (2) under captive screw (1).
3. Using screwdriver, tighten captive screw (1).
FOLLOW-ON MAINTENANCE: Install case (para 2-39).