| TM 11-5820-670-30
2-45. A8700 MODULES AND ASSEMBLY REPLACEMENT. (CONT)
Modules A8100 through A8400 and A8600 are secured with captive screws. Steps 3 and
4 are typical for all modules.
3. Using screwdriver, loosen captive screws (5).
CAUTION
To prevent damage to pins, do not twist module from side to side.
4. Carefully pull module (6) off board to release from pins.
NOTE
Filter module is secured with locknuts and is soldered to printed circuit board.
5. Using wrench, remove locknuts (7).
CAUTION
Care must be taken when performing next step to prevent damaging printed circuit
board.
7. Carefully pull module (9) off board.
2-173
|