| TM 11-5820-670-30
2-41. A4000 MODULES AND ASSEMBLY REPLACEMENT. (CONT)
INSTALLATION (CONT)
NOTE
Before installing FL4002 filter, establish whether a 50 kHz or WIDE BAND operation mode
will be used. The position of FL4002 filter will depend on operation mode selected. See
detail A for 50 KC operation mode and detail B for WIDE BAND operation mode.
NOTE
Modules FL4001 and FL4002 are secured with locknuts. Steps 3 and 4 are typical for both
modules.
Module location is stamped on board.
2-156
|