TM 11-5820-670-30
2-37. HOMING ADJUSTMENT.
TEST EQUIPMENT AND MATERIALS
Maintenance Kit MK-1035/ARC-131
Signal Generator AN/URM-103
Power Signal PP-2953/U
Fuseholder MX-1730/U
All cables are part of MK-1035/ARC
TEST SETUP
Connect equipment as shown in test setup diagram. Turn on all equipment and allow at least 5 minutes
for warmup.
ADJUSTMENT PROCEDURE
1. Set control unit mode switch to HOME, SQUELCH switch to CARR, and frequency selectors to
31.00 MHz.
2. Set test set LEFT and RIGHT HOMER ATTEN to 0 db.
3. Tune signal generator to 31.00 MHz and adjust LO-HI RF SET TO LINE control for minimum
output.