| TM 11-5820-670-30
2-34. NARROW BAND DEVIATION ADJUSTMENT. (CONT)
INITIAL EQUIPMENT CONTROL SETTINGS
Set equipment controls as indicated in the following table.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
T/R
MODE SWITCH
TS-2575/ARC-131
fully clockwise
VOL
DIS
SQUELCH switch
60.05 MHz
FREQ sel
WIDE BAND
WIDE BAND-NAR BAND
OFF
TRANSMIT switch
1000 Hz
OUTPUT FREQUENCY
AN/URM-127
0.39 volt as observed on
AMPLITUDE CONTROL
ME-30E/U
ADJUSTMENT PROCEDURE
1. Set TS-2575/ARC-131 TRANSMIT switch to ON.
EL1AT242
2. Adjust potentiometer R8605, on module A8600, to provide 8 kHz deviation as indicated on
deviation meter.
2-141
|