2-28. RF AMPLIFIER ASSEMBLY A6500 ALINEMENT. (CONT)
INITIAL EQUIPMENT CONTROL SETTINGS
Set equipment controls as indicated in the following table.
CONTROL AND SWITCH SETTINGS
EQUIPMENT
CONTROL OR SWITCH
POSITION/SETTING
CONTROL UNIT
Mode Selector
T/R
SQUELCH
DIS
FREQ sel
65.00 MHz
TS-2575/ARC-131
HI/LO
HI
AGC switch
OFF
ALINEMENT PROCEDURE
NOTE
During alinement, maintain at least 12 to 15 watts output power. Rf amplifier is activated
by switching TRANSMIT switch on test set to ON.
EL1AT229