2-26. TROUBLESHOOTING CHARTS. (CONT)
CHART 2-23
Homing Needle Indication Troubleshooting
(Sheet 2 of 3)
CHECK FOR CONTINUITY
BETWEEN TP4809 AND
PIN 9 OF CONNECTOR P4801,
SEE ILLUSTRATION, SH 3
AND FO-12 FOR PIN
LOCATION.
C H E C K FOR CONTINUITY
ADJUST R2106 FOR A
BETWEEN PIN 9 OF
READING OF +16 VDC. SEE
CONNECTOR P4801 AND
I L L U S T R A T I O N . IF ADJUST-
T P 4 5 0 1 . SEE ILLUSTRATION,
MENT IS NOT POSSIBLE,
SH 3 AND F0-12.
REPLACE A2100 (PARA 2-50).