| TM 11-5820-670-30
2-26. TROUBLESHOOTING CHARTS. (CONT)
CHART 2-13
Transmitter Power Output (HI) Troubleshooting
(Sheet 1 of 3)
NOTES
Frequency should be within 350 KHz of the
control unit setting from 30.00 to 52.95 MHz
and within 450 KHz for frequencies at 53.00
to 75.95 MHz.
CONNECT EQUIPMENT AS
SHOWN IN TRANSMITTER
POWER OUTPUT PERFOR-
MANCE TEST (PARA 2-11).
EL1AT208
REPLACE MODULE A6300
PERFORM TRANSMITTER
ON A6000 ASSEMBLY
POWER OUTPUT PERFOR-
MANCE TEST (PARA 2-11).
2-91
|