| TM 11-5820-670-30
2-20. C-7088/ARC-131 MODE SWITCH SELECTION AND FRONT PANEL ILLUMINATION TEST.
(CONT)
TEST PROCEDURE
Set C-7088/ARC-131 MODE SWITCH to OFF and SQUELCH switch to DIS.
Set frequency selectors on C-7088/ARC-131 for 30.95 MHz.
Swing open amplifier modulator assembly on receiver-transmitter to permit viewing of MHz indi-
cator on gearbox assembly.
Swing open if. amplifier assembly on receiver-transmitter to permit viewing kHz indicator on
gearbox assembly.
Place test set +28 VDC ON-OFF switch to ON.
Adjust variable power source for + 27.5 VDC as indicated on INPUT VOLTAGE meter.
Place test set PILOT-ON switch to ON.
STANDARD. Control panel lamps illuminate.
8. If control panel lamps do not illuminate, see troubleshooting chart 2-24, item 1.
9. Set C-7088/ARC-131 MODE SWITCH to T/R.
10. Observe TEST METER indication on receiver-transmitter.
STANDARD. Midscale indication on TEST METER.
11. If TEST METER indication is not at midscale, see troubleshooting chart 2-24, item 2.
12. Set C-1611 D/AIC Transmit-lnterphone selector to 1.
13. Set C-1611 D/AIC RECEIVER 1 to ON and adjust VOL fully clockwise.
14. Set test set TRANSMIT switch to MOM.
STANDARD. Receiver-transmitter power supply blower motor should run.
15. If blower motor is not operating, see troubleshooting chart 2-24, item 3.
16. Set test set TRANSMIT switch to OFF.
17. Set ME-26 D/U FUNCTION switch to + and set RANGE for 30 V.
18. Set C-7088/ARC-131 MODE SWITCH to HOME.
19. Connect test probe from the ME-26 D/U to TP4504 located on rf control assembly of receiver-
transmitter.
STANDARD. + 27.5 VDC at TP4504.
20. If the voltage level at TP4504 is not 27.5 vdc, see troubleshooting chart 2-24, item 4.
2-42
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |