| TM 11-5820-670-30
2-13. TRANSMlllER DEVIATION NARROW BAND TEST.
PURPOSE
This test checks the transmitter deviation when the rt is transmitting rf signals. Deviation occurs as a
result of transmitting harmonic and beat frequencies.
TEST EQUIPMENT AND MATERIALS
Maintenance Kit MK-1035/ARC-131
Signal Generator AN/URM-127
Electronic Voltmeter ME-30(E)/U
Modulation Meter ME-57/U
Power Supply PP-2953/U
All cables are part of MK-1035/ARC
TEST SETUP
Connect equipment as shown in test setup diagram. Turn on all test equipment and allow at least
5 minutes for warmup.
EL1AT149
2-26
|