| TM 11-5820-670-30
2-11. TRANSMITTER POWER OUTPUT TEST. (CONT)
INITIAL EQUIPMENT CONTROL SETTINGS
Set equipment controls as indicated in the following table.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
T/R
MODE SWITCH
TS-2575/ARC-131
Maximum (clockwise)
VOL
DIS
SQUELCH
30.00 MHz
FREQ sel
HI
HI-LO switch
OFF
TRANSMIT switch
FWD 100
Selector switch
TS-2609/U
1
Transmit-lnterphone selector
C-1611 D/AIC
ON
RECEIVER 1 switch
TEST PROCEDURE
CAUTION
To avoid damage to wattmeter, ensure selector switch is at FWD 100 when receiver-
transmitter HI-LO switch is in the Hi position.
1. Set test set TRANSMIT switch to ON. Observe wattmeter indication.
STANDARD. 10 watts minimum
2. If wattmeter indicates less than 10 watts, see troubleshooting chart 2-13.
3. Repeat steps 1 and 2, adjusting TS-2575/ARC-131 for each of the following frequencies:
42.00 MHz, 52.95 MHz, 53.00 MHz, 65.00 MHz, and 75.95 MHz.
4. Set test set TRANSMIT switch to OFF.
5. Set wattmeter selector switch to FWD 10.
6. Set receiver-transmitter XMTR HI-LO switch to LO.
7. Set TRANSMIT switch on test set to ON. Observe wattmeter indication.
STANDARD. 0.5 watts minimum
8. If wattmeter indication is less than 0.5 watts, see troubleshooting chart 2-14.
9. Repeat steps 4 through 8, adjusting TS-2575/ARC-131 for each of the following frequencies:
42.00 MHz, 52.95 MHz, 53.00 MHz, 65.00 MHz, and 75.95 MHz.
2-23
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |