2-7. RECEIVER SENSITIVITY, QUIETING, AND LIMITING TEST. (CONT)
POSlTION/SETTING
CONTROL OR SWITCH
EQUIPMENT
Adjust as required in test
BAND SWITCH and RF TUNING CONTROL
AN/URM-103
procedures.
EXT MOD
FUNCTION switch
LO 0-10 KUV
RF OUTPUT switch
LO-HI RF SET to LINE control and LO
Adjust for 10 microvolt.
RF UV
10
DEVIATION RANGE KHZ switch
Midrange position
DEVIATION control
SET LEVEL
FUNCTION switch
TS-723 A/U
+20 db
Meter RANGE
AF
AF-RF switch
X 10
RANGE
10
Freq dial
AN/URM-127
X 100
FREQ RANGE MULTIPLIER
Adjust as required to produce
OUTPUT CONTROL
8 kHz deviation on
AN/URM-103.
TEST PROCEDURE
1. Adjust AN/URM-103 signal generator output to 30.00 MHz (indicated by maximum audio on
TS-723A/U meter) 0.5 microvolt, 8 kHz deviation.
2.  Adjust the signal INPUT control on TS-723A/U for a 0 db reference indicated on meter.
3.  Set TS-723A/U function switch to DISTORTION position and adjust coarse and fine FREQUENCY
controls along with BALANCE control for a minimum meter indication.
4.  Observe TS-723A/U meter indication in db. Compare the indication in db below the reference
set in step 2.
STANDARD. 10 db minimum
5. If meter indication is not at Ieast 10 db below the reference, see troubleshooting chart 2-9.
6. Repeat steps 1 through 5, adjusting TS-2575/ARC-131 test set for each of the following
frequencies: 41.00 MHz, 52.00 MHz, 53.00 MHz, 65.00 MHz, and 75.95 MHz.
2-13