2-5. AUDIO POWER OUTPUT AND DISTORTION TEST. (CONT)
INITIAL EQUIPMENT CONTROL SETTINGS
Set equipment controls as indicated in the following table.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
T/R
MODE SWITCH
TS-25751ARC-131
Maximum (clockwise)
VOL
DIS
SQUELCH
60.05 MHz
FREQ sel
10
Freq dial
AN/URM-127
X 100
FREQ RANGE MULTIPLIER
As required in test
OUTPUT CONTROL
procedures.
METER
FUNCTION switch
TS-723A/U
AF
AF-RF switch
10
Meter RANGE
X 10
Freq RANGE
100
Coarse FREQUENCY
Adjust to 60.05 MHz.
BAND SWITCH and RF TUNING CONTROL
AN/URM-103
EXT MOD
FUNCTION switch
LO 0-10 KUV
RF OUTPUT switch
LO-HI RF SET to LINE control
Adjust for 10 microvolt
and LO RF UV
output.
10
DEVIATION RANGE KHZ switch
Midrange position
DEVIATION control
NOTE
With mode switch in T/R position, external power is applied to the receiver-transmitter.
The receiver-transmitter requires a 1-minute warmup before measurements are made.
TEST PROCEDURE
1.
Set FUNCTION switch on signal generator AN/URM-103 to EXT MOD and adjust frequency for a
60.05 MHz, 10 microvolt output.
2.  Adjust AN/URM-127 for 8 kHz deviation as indicated on AN/URM-103 DEVIATION KHZ meter.
3.  Determine that RECEIVER AUDIO OUTPUT J107 HI-LO are connected to METER terminals of
spectrum analyzer TS-723A/U.
2-7