1-51. RF CONTROL ASSEMBLY P/O MODULE A4500 (HOMING MODE).
DIODE SWITCH
EL1AT125
Rf signals entering the left and right homing antennas are alternately switched through the diode
switch to the rf attenuator circuit at a 100 Hz rate. The 100 Hz square wave from the 100 Hz oscillator is
used to bias the diodes in the diode switch. When the square-wave bias voltage is positive(+), rf
signals from the left homing antenna are coupled through the diode switch to the rf attenuator circuit.
When the wave becomes negative (-), rf signals from the right homing antenna are coupled to the rf
attenuator.
RF Attenuator
EL1AT126
1-52