Figure 8-3. Control circuit board (removed and open to show detail).
Section II. INSTALLATION
8-5. Mechanical
8-6. Electrical
Connect the black and white leads of the input cable to
The unit must be operated with the carrying handles up.
a power source capable of delivering 30 amperes at a
The CN-1146/F RC-93 relies on natural convection
cooling only, and this must be considered when
voltage between 60 and 150 volts from 48 to 63 Hz.
mounting the unit. Mounting in a confined or poorly
The green lead on the input cable should be connected
to ground. The load may be plugged into the
ventilated space should be avoided. Holes are provided
receptacles on the regulator..
in the bottom brackets for permanently mounting the
unit.