| TM 11-5820-509-35
circuit and the +20V ON-OFF switch is in the ON
6-21. Test Fixture for Radio Frequency
position.
Oscillator 0-1032/PRC-47
(3) +20V 1/4 AMP fuse. This protective
device is connected to the +20 volts dc primary power
circuit to protect it from overload.
(4) +20 V CURRENT meter. This 0 - 60
0-1032JPRC-47 contains all switches, jacks, meter and
milliammeter indicates the amount of current being
lamps necessary to electrically test and adjust the
drawn by the module under test.
module without providing a complete AN/PRC-47 Radio
Set. Power for the test fixture and the module under
(5) PUSH TO READ button. This shunting
test is provided externally and is connected to the test
switch is opened when pressed to permit the +20 V
fixture by a specially fabricated cable attached to power
CURRENT meter to indicate the module current drain.
connector J2 at the rear of the test fixture.
(6) Coaxial connectors are provided for the
b. The operating controls on the front panel of the
connection of signal leads and test equipment and these
test fixture (fig. 6-9) perform the following functions:
are self-explanatory.
(1) +20V ON-OFF switch. This toggle switch
c. The piece parts required for fabrication of the
controls the +20 volts dc primary power circuit to the
test fixture are listed in the following chart and
module under test.
suggested parts placement is shown in figure 6-26.
Schematic diagram {fig. 7-19) illustrates the internal
(2) +20V lamp. This indicator is lit when
circuit of the test fixture.
power is connected to the +20 volts dc primary power
6-54
|