| TM 11-5820-509-35
Symbol
Description
Mfgr Part No.
Mfgr Code
T1
Transformer (FSN 5950-982-3748ZX)
BC3069
97315
VR1
Semiconductor device, zener diode 39 v, 5%
1N975B
VR2
Semiconductor device, zener diode 6.2 v, 5% (FSN 5960-752-
1N753A
0179)
XDS1
Lampholder
95408H935
72619
XF1 thru XF4
Fuseholder (FSN 5920-284-7144)
HKPH
71400
Note. All manufacturer's codes are 5-digit numbers. The corresponding manufacturer's name and address are listed in SB 708-42 Catalog Handbook (H4-2).
6-20. Test Fixture for Power Supply PP-
(6) +23V 15 AMP fuse.
This protective
3518/PRC-47
device is connected to the +23 volt primary power circuit
to protect it from overload.
a. The test fixture for Power Supply PP-3518/PRC-
(7) BLOWER ON-OFF switch. This toggle
47 contains all switches, jacks, meters, and lamps
switch controls the 115 volts, 60 Hz primary power
necessary to electrically test and adjust the module
applied to the blower.
without providing a complete AN/PRC-47 Radio Set.
(8) BLOWER 60 CPS 1/2 AMP fuse. This
Power for the test fixture and the module under test is
protective device is connected to the 115 volts, 60 Hz
provided externally and is connected to the test fixture
primary power circuit that energizes the blower motor
by a specially fabricated cable attached to power
and protects it from overload.
connector J2 at the rear of the test fixture.
(9) HV ON-OFF switch. This toggle switch
b. The operating controls on the front panel of the
enables the push-to-talk relay (K1) in the power supply
test fixture (fig. 6-8) perform the following functions:
module when high voltage output is desired.
(1) 115 VAC ON-OFF switch. This toggle
(10) VOLTAGE SEL switch. This 9-position
switch controls the 115 volts, 400 Hz ac and interlocks
rotary switch selects the power supply module circuit to
the +23 volt dc circuit between the module under test
be monitored and connects it to the DC VOLTAGE
and the test fixture load circuits.
meter, or the AC VOLTAGE, jacks for measurement.
All power supply module outputs can be selected by this
(2) 115 VAC lamp. This indicator is lit when
switch.
power is connected to the 115 volts, 400 Hz primary
power circuit and the 115 VAC ON-OFF switch is in the
(11) DC VOLTAGE meter.
This 0-lO0
ON position.
microammeter is used to indicate the several dc output
voltages of the power supply module as selected by the
13) 115 VAC 5 AMP fuse. This protective
VOLTAGE SEL switch.
device is connected to the 115 volts, 400 Hz primary
power circuit to protect it from overload.
(12) AC VOLTAGE jacks. These jacks are
provided to connect an external ac instrument for
(4) +23V ON-OFF switch. This toggle switch
measuring the filament voltage output of the power
controls the +23 volts dc primary power circuit and
supply module.
interlocks it with the 115 volts, 400 Hz primary power
circuits to prevent both being energized at one time.
c. The piece parts required for fabrication of the
(5) +23V lamp. This indicator is lit when
test fixture are listed in the following chart and
power is connected to the +23 volt primary power circuit
suggested parts placement is shown in figures 6-24 and
and the +23V ON-OFF switch is in the ON position.
internal circuit of the test fixture.
6-50
|