| TM 11-5820-509-35
input voltages to the test fixture and the module.
+24 volts power input to the module to determine the
circuit current drain.
(2) POWER ON lamp. This indicator is lit
when power is connected to the test fixture and the
(7) MODULE CURRENT meter. This 0- 150
POWER ON-OFF switch is in the ON position.
millimmeter indicates the dc current drain of the module.
(3) POWER 24 VDC 1/2 AMP fuse. This
(8) VOX ON lamp.
This indicator is lit
protective device is connected in the +24 volts dc
whenever the PTT ON-OFF-MOM ON switch is placed
primary power circuit to protect it from overload.
to ON or MOM ON.
(4) PTT ON-OFF-MOM ON switch.
This
(9) SIDETONE GATE ADJUST control. This
toggle switch enables the transmit mode in the module
potentiometer varies the sidetone gate bias applied to
when placed in either the ON or MOM ON positions for
the receiver amplifier circuit of the module.
simulated voice operation.
(10) Test jacks and binding poets are provided
(5) KEY ON OFF-MOM ON switch. This
for the attachment of signal leads and test equipment
toggle switch enables the transmit mode in the module
and are self-explanatory.
when placed in either the ON or MOM ON positions for
c. The piece parts required for fabrication of the
simulated telegraph operation.
test fixture are listed in the following chart and
(6) +20V/ +24V switch. This rotary switch
suggested parts placement is shown in figures 6-17 and
places the MODULE CURRENT meter in series with
either the +20 volts power input to the module, or the
internal circuit of the test fixture.
6-38
|