| TM 11-5820-509-35
Ref des
MCN effectivity
Description of change
A3R76
A3C187
600
Changed to 27 pF, was 20 pF.
A3C42
Plan 737
Changed to 270 pF, was 190 pF.
A3C248 /
900
Changed each to 8-50 pF, was 5-30 pF.
A3C250/
A3C252
A3C249
900
Changed to 287 pF, was 300 pF.
A3C251
900
Changed to 165 pF, was 200 pF.
A3C253
900
Changed to 133 pF, was 120 pF.
A3C255
900
Changed to 91 pF, was 82 pF.
A3C257
900
Changed to 62 pF, was 68 pF.
A3C259
900
Changed to 39 pF, was 56 pF.
Change 2 1-3
|