| TM 11-5820-401-34-3/0967-LP-432-3060
SILICON VERSION A5300A SQUELCH FILTER ALINEMENT. (CONT)
5-24.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table. When using alternate equipment, inject 1,000-v rf at a frequency that gives maximum TP5008
voltage. Use variable external modulation around 150-Hz reference. Deviation will vary according to
alinement requirements.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
TRACK
POWER
AN/USM-207 (to
MIN (fully counterclockwise)
DISPLAY
verify AN/URM-127
0.1 v
SENSITIVITY
low-frequency
1 (black knob)
GATE TIME
output)
FREQ
FUNCTION
TRACK
POWER
AN/USM-207 (to
MIN (fully counterclockwise)
DISPLAY
verify AN/URM-103
PLUG IN
SENSITIVITY
high-frequency
FREQ
FUNCTION
output)
103 (black knob)
GATE TIME
DIRECT
DIRECT/HETERODYNE
0.3 V MAX (both switches to left)
INPUT
100
FREQUENCY TUNING-MC
5-116
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |