IF DISCRIMINATOR A4200 ALINEMENT. (CONT)
5-19.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table. If using alternate equipment, inject 20-v rf at 30 MHz, 1-kHz modulation; 8-kHz deviation.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
ON-RESET
POWER
R-442/VRC
o
A
BAND
30.00
MC-TUNE-KC
Fully clockwise
VOLUME
NEW OFF
SQUELCH
OPERATE
OPERATE/OFF/STAN D BY
AN/URM-103
1000 Hz
FUNCTION
o
R
BAND SWITCH
30.00
RF TUNING
10
DEVIATION RANGE KHZ
LO, 0-10 KUV
RF OUTPUT
Fully counterclockwise
DEVIATION
Adjust until needle on IF UV RF SET TO
RF SET TO LINE
LINE meter is over red line
20 v
LO RF UV
5-102
|