5-15. CRYSTAL REFERENCE SYSTEM (CRS) TEST. (CONT)
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table. If using alternate equipment, inject 100-v rf at 30 MHz; 1-kHz modulation; 8-kHz deviation.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
POWER
ON-RESET
R-442/VRC
BAND
30. 0
MC-TUNE-KC
C l o c k w i s e one-third turn
VOLUME
NEW OFF
SQUELCH
OPERATE (allow 15-minute warmup)
OPERATE/OFF/STAND BY
AN/URM-103
1000 Hz
FUNCTION
o
B
BAND SWITCH
30.00 (check on counter)
RF TUNING
10
DEVIATION RANGE KHZ
LO, 0-10 KUV
RF OUTPUT
Fully counterclockwise
DEVIATION
Adjust until needle on IF UV RF SET TO LINE
RF SET TO LINE
meter is over red line
LO RF UV
100v
AN/USM-207
POWER
TRACK (allow 5-minute warmup)
DISPLAY
MIN (fully counterclockwise)
PLUG IN
SENSITIVITY
FREQ
FUNCTION
104 (black knob)
GATE TIME
DIRECT/HETERODYNE
DIRECT
0.3 V MAX (both switches to left)
INPUT
100
FREQUENCY TUNING-MC
TEST PROCEDURE
NOTE
30 MHz. The rf level must be increased temporarily to enable the frequency counter to
display. Adjust the AN/URM-103 RF TUNING control as necessary, reset to 100-v rf
level; then disconnect the T-connector from the counter.
1.
Turn AN/URM-103 DEVIATION control clockwise until DEVIATION KHZ meter reads 8 kHz.
1000-Hz tone will be heard on speaker. If no tone is heard, CRS may be defective. Make
sure T-connector is disconnected from counter.
2.
Adjust R-442/VRC VOLUME control for comfortable level.
5-91
|