4-22.
A5300 SQUELCH FILTER ALINEMENT. (CONT)
TEST SETUP. Connect the equipment as shown in test setup diagram
. Remove R.442/VRC top
.-
cover. (See paragraph 2-7.)
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table. Inject 1000V rf at 30 MHz, 150-Hz modulation; 2-kHz deviation
CONTROL AND SWITCH SETTINGS
EQUIPMENT
CONTROL OR SWITCH
POSITION/SETTING
R-442/VRC
POWER
ON -RESET
BAND
MC-TUNE-KC
30.00
VOLUME
Fully counterclockwise
SQUELCH
NEW ON
MK-1978/VRC
AUX POWER
ON
AUX RCVR
NORMAL
AUDIO
MUTED
SQUELCH
ON
KEY
RCVE
4-131
|