| TM 11-5820-401-.34-3/0967- LP-432-3060
IF DISCRIMINATOR A4200 ALINEMENT. (CONT)
4-18.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table. Inject 20-v rf at 30 MHz, 1-kHz modulation; 8-kHz deviation.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
POWER
ON-RESET
R-442/VRC
BAND
A
MC-TUNE-KC
30.00
Fully clockwise
VOLUME
NEW OFF
SQUELCH
MK-1978/VRC
AUX POWER
ON
NORMAL
AUX RCVR
MUTED
AUDIO
ON
SQUELCH
KEY
RCVE
See test setup diagram
AN/GRM-114A;
MM-100E