| TM 11-5820-401-34-3/0967-LP-432-3060
4-13.
TROUBLESHOOTING FLOW CHARTS. (CONT)
CHART 4-3
SINAD Test Failure Troubleshooting A1000 Assembly
(Sheet 1 of 8)
NOTES
1. Ground probe B. Adjust MM-100E RANGE
switch as needed.
2. Power supply and battery input voltage should
already have been checked.
3. Make sure that P1005 is connected to J1005
and that the AN/GRM. 114A 1-kHz control is
adjusted for 8-kHz deviation on the DEV meter
before taking the following readings.
4-68
|