| TM 11-5820-401-34-3/0967-432-3060
4-5. OLD SQUELCH TEST. (CONT)
OLD SQUELCH Test at 30.00 MHz
1. Turn AN/GRM-114A RF LEVEL control (1) slowly clockwise until CALL lamp lights.
STANDARD. R-442/VRC CALL lamp should light while AN/GRM-114A RF LEVEL is at or below
0.7 Uv.
2. If RF LEVEL control (1) is more than 0.7v, see troubleshooting chart 4-5.
3. Remove cable from R-442/VRC ANTENNA port.
STANDARD. R-442/VRC CALL lamp should go out.
4. If R-442/VRC CALL lamp does not go out, see troubleshooting chart 4-5.
5. Reconnect cable to R-442/VRC ANTENNA port.
STANDARD. R-442/VRC CALL lamp should light.
6. If CALL lamp does not light, see troubleshooting chart 4-5.
OLD SQUELCH Test at Other Frequencies
7. Return AN/GRM-114A RF LEVEL control (1) to minimum setting.
8. Set AN/GRM-114A RF FREQUENCY MHz thumbwheels (3) and R-442/VRC MC-TUNE-KC
switch to frequency control settings listed below. Repeat steps 1 through 7 at each
frequency.
NOTE
Change R-442/VRC to BAND
at 53, 65, and 75 MHz.
4-13
|