RECEIVER SENSITIVITY TEST. (CONT)
4-3.
STANDARD. MM-100E blue SINAD scale should indicate 10 or greater at each frequency.
7. If MM-100E indication falls below 10 at any frequency, see troubleshooting chart 4-2.
4-4.
NEW SQUELCH TEST.
PURPOSE. This test checks the sensitivity of the R-442/VRC squelch modules (A5200, A5300) to
the NEW SQUELCH signal (150Hz) at several carrier frequencies. The 150-Hz signal is injected into
receiver. Proper operation of the squelch modules is verified by CALL lamp response to carrier signal
strength at or below a 0.5-v rf level.
TEST EQUIPMENT AND MATERIALS
Power Supply PP-1104(*)/G
Test Set AN/GRM-114A
Rf Cable RG-58/U
Maintenance Kit MK-1978/VRC
TEST SETUP. Connect equipment as shown in test setup diagram
.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table.