RECEIVER SENSITIVITY TEST.
PURPOSE. This test checks the ability of the R-442/VRC to detect low-level rf signals by measuring
its SINAD at several frequencies. SINAD gives receiver sensitivity in terms of the following ratio:
signal + noise + distortion/noise + distortion.
SINAD is expressed in decibels. The better a receiver's SINAD, the better signals, even weak ones,
can be heard over unwanted internal noise. The SINAD for the R-442/VRC should be at least -10 db
(from a zero-db reference) when the rf level is 0.5 v
TEST EQUIPMENT AND MATERIALS
Power Supply PP-1104(*)/G
Test Set AN/GRM-114A
Maintenance Kit MK-1978/VRC
Rf Cable RG-58/U
TEST SETUP. Connect equipment as shown in test setup diagram
.