| TM 11-5820-401-34-3/0967- LP-432-3060
4-2. VOLUME CONTROL TEST. (CONT)
TEST SETUP. Connect equipment as shown in test setup diagram
.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table.
CONTROL AND SWITCH SETTINGS
CONTROL OR SWITCH
POSITION/SETTING
EQUIPMENT
AUX POWER
ON
MK-1978/VRC
AUDIO
MUTED
KEY
RCVE
X-MODE (RT)
NORMAL
AUX RCVR
NORMAL
SQUELCH
ON
R-442/VRC
BAND
MC-TUNE-KC
30. 00
SQUELCH
OLD OFF
LIGHT
ON
VOLUME
Fully counterclockwise
ON
POWER
4-3
|