| TM 11-5820-401-34-3/0967-LP-432-3060
3-28.
SILICON VERSION A5200A SQUELCH AMPLIFIER ALINEMENT, OLD SQUELCH LEVEL. (CONT)
CONTROL AND SWITCH SETTINGS (CONT)
CONTROL OR SWITCH
POSITION/SETTING
EQUIPMENT
OPERATE/OFF/STAND BY
OPERATE
AN/URM-103
FUNCTION
EXT MOD
BAND SWITCH
RF TUNING
64.00
DEVIATION RANGE KHZ
10
RF OUTPUT
LO, 0- 10 KUV
DEVIATION
Fully counterclockwise
RF SET TO LINE
Adjust until needle on IF UV RF SET
TO LINE meter is over red line
LO RF UV
20v
POWER
ON
AN/URM-127
FREQ RANGE MULTIPLIER
x100
FREQ RANGE DIAL
73
ATTENUATOR
x10
Turn clockwise for 2.2-volt reading on
OUTPUT CONTROL
panel voltmeter
FREQ METER
ON
POWER
TRACK
AN/USM-207
DISPLAY
MIN (fully counterclockwise)
(to verify AN/
0.1 v
SENSITIVITY
URM-127 IOW-
1 (black knob)
GATE TIME
frequency output)
FREQ
FUNCTION
POWER
TRACK
AN/USM-207
DISPLAY
MIN (fully counterclockwise)
(to verify AN/
PLUG IN
SENSITIVITY
URM-103 high-
FREQ
FUNCTION
frequency output)
103 (black knob)
GATE TIME
DIRECT/HETERODYN E
DIRECT
INPUT
0.3 V MAX (both switches to left)
100
FREQUENCY TUNING-MC