| TM 11-5820-401-34-3/0967-LP-432-3060
3-27. A5200 SQUELCH AMPLIFIER ALINEMENT, OLD SQUELCH LEVEL. (CONT)
11. Adjust AN/URM-103 DEVIATION control for ME-30(*)/U reading 4 db less than reading
recorded in step 5.
12. Check R-442/VRC CALL light. If light is out, go to step 13. If light is on, go to step 14.
13. CALL LIGHT OUT. Turn R5216 (3) counterclockwise slowly and stop at point where light just
comes on. (See test setup diagram
14. CALL LIGHT ON. Turn R5216 (3) clockwise until light goes out, then repeat step 13.
OLD SQUELCH Final Test
15. Adjust ANLJRM-103 DEVIATION control for 8-kHz reading on DEVIATION KHZ meter.
16. Set AN/USM-127 FREQ RANGE MULTIPLIER to x10.
17. Set AN/USM-127 FREQ RANGE DIAL to 35 (350 Hz). R-442/VRC CALL light should be on.
NOTE
CALL light must stay on through range of 350 to 3500 Hz.
18.
Rotate FREQ RANGE DIAL fully clockwise to 2000 Hz. CALL light should stay on.
19.
Rotate FREQ RANGE DIAL fully counterclockwise.
20.
Set FREQ RANGE MULTIPLIER to x100,
21.
Rotate FREQ RANGE DIAL to 35 (3500 Hz). CALL light should stay on.
NOTE
If R-442/VRC fails the OLD SQUELCH Final Test, replace the A5300 module and repeat
the entire alinement procedure.
3-28. SILICON VERSION A5200A SQUELCH AMPLIFIER ALINEMENT, OLD SQUELCH LEVEL.
PURPOSE. This procedure adjusts the receiver sensitivity to the OLD SQUELCH signals which
include internal noise and the received carrier.
TEST EQUIPMENT AND MATERIALS
Matching Unit CN-901/U
Signal Generator AN/URM-103
T-Connector UG-274/U
Frequency Counter AN/USM-207
Loudspeaker LS-454/U
Power Supply PP-1104(*)/G
Voltmeter ME-30(*)/U
Signal Generator AN/URM-127
Maintenance Kit MK-1978/VRC
3-126
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |