| TM 11-5820-401-34-3/0967-LP-432-3060
3-23. A500 SQUELCH FILTER ALINEMENT. (CONT).
17. FREQUENCY BELOW 149 HZ. Turn R5301 (3) clockwise slightly. Reset AN/URM-127 FREQ
RANGE DIAL to obtain a peak reading on ME-30(*)/U.
18. Check frequency on AN/USM-207.
Repeat steps 17 and 18 until peak ME-30(*)/U reading is obtained at a frequency between 149
and 151 Hz.
3-24.
SILICON VERSION A5300A SQUELCH FILTER ALINEMENT.
PURPOSE. This procedure adjusts the gain of Squelch Amplifier A5200A in the NEW SQUELCH mode
of operation. Alinement of the A5300A squelch filter must be done before the Silicon Version Squelch
Amplifier A5200A Alinement, NEW SQUELCH Level, paragraph 3-26.
TEST EQUIPMENT AND MATERIALS
Matching Unit CN-901/U
Signal Generator AN/URM-103
T-Connector UG-274/U
Signal Generator AN/URM-127
Loudspeaker LS-454/U
Power Supply PP-1104(*)/G
Voltmeter ME-30(*)/U
Frequency Counter AN/USM-207
Maintenance Kit MK-1978/VRC
TEST SETUP. Connect the equipment as shown in test setup diagram
. Remove R-442/VRC top
cover. (See paragraph 2-7.)
3-115
|