3-19. IF DISCRIMINATOR A4200 ALINEMENT. (CONT)
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
EQUIPMENT
CONTROL OR SWITCH
POWER
ON-RESET
R-442/VRC
BAND
MC-TUNE-KC
30.00
Fully clockwise
VOLUME
SQUELCH
NEW OFF
OPERATE
OPERATE/OFF/STAND BY
AN/URM-103
1000 Hz
FUNCTION
BAND SWITCH
RF TUNING
30.06
10
DEVIATION RANGE KHZ
LO, 0-10 KUV
RF OUTPUT
DEVIATION
Fully counterclockwise
RF SET TO LINE
Adjust until needle on IF UV RF SET TO LINE
meter is over red line
LO RF UV
20 v
POWER
AN/USM-207
TRACK
DISPLAY
MIN (fully counterclockwise)
SENSITIVITY
PLUG IN
FUNCTION
FREQ
103 (black knob)
GATE TIME
DIRECT/HETERODYNE
DIRECT
INPUT
0.3 V MAX (both switches to left)
FREQUENCY TUNING-MC
100
MK-1978/VRC
POWER
ON
AUX RCVR
NORMAL
AUDIO
MUTED
SQUELCH
ON
KEY
RCVE
ALINEMENT PROCEDURE
NOTE
Check the frequency counter to make sure that the signal generator is outputting exactly
30 MHz. The rf level must be increased temporarily to enable the frequency counter to
display. Adjust the AN/URM-103 RF TUNING control as necessary, reset to 20-v rf
level; then disconnect the T-connector from the counter.