Click here to make tpub.com your Home Page

Page Title: STANDARD. R-442/VRC CALL lamp should remain lit.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM
11-5860-401-34-3/0967-LP-432-3060
RECEIVER SELECTIVITY TEST. (CONT)
3-10.
4. Increase AN/URM-103 LO RF UV level to twice the reading noted in step 3.
STANDARD. R-442/VRC CALL lamp should remain lit.
5.
If R-442/VRC CALL lamp goes off, see troubleshooting chart 3-6.
Change AN/USM-207 GATE TIME to 102.
6.
7.
Reattach T-connector to AN/USM-207.
8.
Adjust AN/URM-103 RF TUNING control for 30.019-MHz (30019.0-kHz) display on AN/USM-
207. To produce display, follow instructions in note under step 1, but reset AN/URM-103 LO RF
UV control to level arrived at in step 4.
9. Disconnect T-connector from AN/USM-207.
STANDARD. R-442/VRC CALL lamp should be off.
10. If R-442/VRC CALL lamp is lit, see troubleshooting chart 3-6.
11. Turn AN/URM-103 RF TUNING control slowly counterclockwise until R-442/VRC CALL lamp
lights.
12. Reattach T-connector to AN/USM-207.
13. Turn AN/URM-103 LO RF UV control clockwise until display appears on AN/USM-207. Note
frequency displayed.
14. Adjust AN/URM-103 RF TUNING control for 29.981-MHz (29981.0-kHz) display on
AN/USM-207.
15. Disconnect T-connector from AN/USM-207.
16. Reset AN/URM-103 LO RF UV control to level arrived at in step 4.
STANDARD. R-442/VRC CALL lamp should be off.
17.
If R-442/VRC CALL lamp is lit, see troubleshooting chart 3-6.
18.
Turn AN/URM-103 RF TUNING control slowly clockwise until R-442/VRC CALL lamp lights.
19.
Reattach T-connector to AN/USM-207.
20.
Turn AN/URM-103 LO RF UV control clockwise until display appears on AN/USM-207. Note
frequency displayed.
21. Subtract frequency noted in step 20 from frequency noted in step 13.
STANDARD. The difference between the two frequencies should beat least 32 kHz.
22. If difference between frequencies noted in steps 13 and 20 is less than 32 kHz, see trouble-
shooting chart 3-6.
23. Increase LO RF UV level to 1000 times reading noted in step 3.
24. Change AN/USM-207 GATE TIME to 104.
25. Reattach T-connector to AN/USM-207.
26. Adjust AN/URM-103 RF TUNING control for 30.41-MHz display on AN/USM-207. To produce
display, follow instructions in note under step 1, but reset AN/URM-103 LO RF UV control to
level arrived at in step 23.
27. Disconnect T-connector from AN/USM-207.
STANDARD. R-442/VRC CALL lamp should be off.
28. If R-442/VRC CALL lamp is lit, see troubleshooting chart 3-6.
29, Turn AN/URM-103 RF TUNING control slowly counterclockwise until R-442/VRC CALL lamp
lights.
30. Reattach T-connector to AN/USM-207.
3-32


Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business