| TM 11-5820-401-34-3/0967-LP-432-3060
3-8.
RECEIVER AUDIO RESPONSE TEST (NORMAL MODE). (CONT)
STANDARD. ME-30(*)/U should indicate between 14 and 22 volts.
26. If ME-30(*)/U indicates below 14 volts or above 22 volts, see troubleshooting chart 3-5.
3-9.
RECEIVER AUDIO RESPONSE TEST (X-MODE).
PURPOSE. This test is similar to the Audio Response Test (Normal Mode). When set up for X-
mode, however, the R-442/VRC responds to a wider band of frequencies because the A5000 tray is
not used. The ability of the receiver to detect and respond flatly to the desired intelligence is verified
by comparing db readings taken at the MK-1978/VRC, X-MODE AUX RCVR jack while injecting several
modulating frequencies to a reference voltage measurement taken at 1-kHz modulation.
R-442/VRC X-MODE SETUP PROCEDURE
1.
Remove bottom cover from R-442/VRC. (See paragraph 2-7).
2.
Raise A4000 tray and secure brace.
Remove Filter FL4002.
3.
Rotate Filter FL4002 180 degrees.
4.
Put Filter FL4002 back into tray.
5.
Set X-MODE-NORMAL Switch S4001, located underneath tray, to X-MODE position.
6.
Release brace and lower A4000 tray.
7.
Replace R-442/VRC bottom cover.
8.
TEST EQUIPMENT AND MATERIALS
Power Supply PP-1104(*)/G
Adapters (two) UG-274 B/U (T-
Frequency Counter AN/USM-207
Connector) and UG-514
Matching Unit CN-901/U
Signal Generator AN/URM-103
Rf Cables (three) RG-58/U
Signal Generator AN/URM-127
Maintenance Kit MK-1978/VRC
Ac Voltmeter ME-30(*)/U
TEST SETUP. Connect test equipment as shown in test setup diagram
3-25
|