3-8. RECEIVER AUDIO RESPONSE TEST(NORMAL MODE). (CONT)
TEST EQUIPMENT SETUP. Connect test equipment as shown in test setup diagram
NOTE:
AN/URM-127 CONNECTED TO AN/URM-103
AT START OF TEST. DOTTED LINE SHOWS
CONNECTION TO AN/USM-207 FOR FRE-
QUENCY VERIFICATION DURING
PROCEDURE.
Turn on test equipment. Allow at least 15 to 30 minutes for warmup.
INITIAL EQUIPMENT CONTROL SETTINGS. Set equipment controls as indicated in the following
table. If using alternate test equipment, adjust for 64.00 MHz, 20-v rf input level, 1-kHz modulation,
and 8-kHz frequency deviation.
CONTROL AND SWITCH SETTINGS
POSITION/SETTING
CONTROL OR SWITCH
EQUIPMENT
100
FREQUENCY TUNING-MC
AN/USM-207
TRACK
POWER
MIN (fully counterclockwise)
DISPLAY
0.3 V MAX (both switches to left)
INPUT
103 (black knob)
GATE TIME
PLUG IN
SENSITIVITY
FREQ
FUNCTION
DIRECT
DIRECT/HETERODYNE
3-22