|
| TM 11-5820-401-34-3/0967-LP-432-3060
GENERAL. (CONT)
3-1.
Each test is complete and may be performed individually. Therefore, you may choose the appropriate
test to verify gross equipment failure or performance degradation of specific stages. However, this
maintenance approach is not recommended. It is best to perform all the tests in sequence. This
systematic maintenance approach will ensure that all faults are found and corrected.
Faults in the R-442/VRC are evidenced by failure of the radio to meet the performance standards found
within the test procedures in bold type. When an R-442/VRC fails to meet a performance standard,
discontinue the test and turn to the troubleshooting chart referred to in the procedure.
3-2. VOLUME CONTROL TEST.
PURPOSE. This test checks the VOLUME control of the R-442/VRC for proper operation. When a
1-kHz tone is injected into the receiver ANTENNA port, the speaker should output a clear tone with no
scratchy sound or sudden drop in volume. The absence of a tone means that the signal is not passing
completely through the R-442/VRC circuitry and could even indicate total equipment failure;
therefore, perform this test before the others in this section.
TEST EQUIPMENT AND MATERIALS
Matching Unit CN-901/U
Power Supply PP-1104(*)/G
Loudspeaker LS-454/U
Frequency Counter AN/USM-207
Maintenance Kit MK-1978/VRC
Signal Generator AN/URM-103
Rf Cables (two) RG-58/U
Adapter (T-Connector) UG-274 B/U
TEST SETUP. Connect equipment as shown in test setup diagram
3-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |