| TM 11-5820-401-34-3/0967-LP-432-3060
2-15. VOLUME CONTROL R101 REPLACEMENT.
MATERIALS/PARTS: Variable Composition Resistor
PRELIMINARY PROCEDURE: Remove front panel. (See paragraph 2-8.)
REMOVAL
1.
Using screwdriver, remove screw (1) and knob (2).
2.
Using wrench, remove nut (3), ET Iockwasher (4), and stop clip (5).
3.
Push potentiometer (6) out of front panel.
4 .
Using soldering iron, carefully unsolder three wires (7) one at o time and resolder on
replacement potentiometer.
INSTALLATION
1.
Push potentiometer (6) into front panel and position stop pin (8) in hold (9).
2.
Install stop clip (5) with short end (10) in hole (9).
3.
Install ET Iockwasher (4) and nut (3).
4.
Using wrench, tighten nut (3).
5.
Install knob (2) and screw (1).
6.
Using screwdriver, tighten screw (1).
FOLLOW-ON MAINTENANCE: Install front panel. (See paragraph 2-8.)