MODULES A1100 THROUGH A1500 REPLACEMENT. (CONT)
2-10.
INSTALLATlON
CAUTION
Before installing modules A1100 through A1300, make sure BAND switch pin (1) on
module (2) is positioned to mate with BAND switch actuating pawl (3) on A1000 as-
sembly (4) . On some A1100 through A1300 modules, spring (5) returns BAND switch to
BAND
position. On these modules, turn BAND switch control to BAND
for
installation then return to BAND
position.
1. Carefully push modules (6) into place.
NOTE
Note locations of different numbered modules.
Make sure spring contacts on modules make contact with partitions between modules.
2. If modules A1100 or A1500 were removed, reconnect green wire (W202/W402) (7) to
J1004 and brown wire (W102) (8) to J1001.