| Page 151. Add chapter 6 after figure 79:
CHAPTER 6
DEPOT INSPECTION STANDARDS
(2) TM 11-5820-398-20, Organizational Main-
98. Applicability of Depot Inspection Stand-
tenance Manual.
ards
(3) TM 11-5820-398-35P, Field and Depot
The tests outlined in this chapter are designed
Maintenance Repair Parts and Special
to measure the performance and capability of a
Tools List.
repaired Radio Set AN/PRC2.5. Equipment that
(4) TM 11-5820-497-35P, Field and Depot
meets the minimum standards stated in the tests
Maintenance Repair Parts and Special
will furnish satisfactory operation, equivalent to
Tools List, Receiver-Transmitters, Radio
that of new equipment.
RT-505/PRC-25 and RT-505A/PRC-25.
c. Modification Work Orders. Perform all applica-
99. Applicable References
ble Modification Work Orders pertaining to Radio
a. Repair Standards. Applicable procedures of
Set AN/PRC-25 before making the tests specified.
the U.S. Army depot performing this test, and the
DA Pam 310-4 lists all available MWO's.
depot standards for repaired signal equipment, form
100. Test Facilities Required
a part of the requirements for testing this equipment.
b. Technical Publications. The following technical
The following equipment, or suitable equivalents,
publications are applicable to Radio Set AN/PRC-
will be employed in determining compliance with the
25:
requirements of this Specific Standard.
a. Test Equipment.
(1) TM 11-5820-398-10, Operator's Manual.
Equipment
Federal stock No.
Technical manual.
Audio oscillator, Hewlett-Packard Model HP-200AB --------------------
6625-519-2384
1
-------------
1
Signal Generator, F. M., Marconi Model 1066A --------------------------
6625-669-0742
Voltmeter, Meter ME-30A/U ------------------------------------------
1
TM
11-6625-320-12
6625692-6553
TM
11-5057
Frequency Meter AN/USM-26-----------------------------------------
1
TM
11-5097
6625-668-9418
S p e c t r u m Analyzer TS-723A/U -----------------------------------------
1
1
TM
11-5129
6625-668-4676
Oscilloscope AN/USM-50A --------------------------------------------
Modulation
Meter
ME-57/U--------------------------------------------------------
1
TM
11-6625-400-12
6625-647-3737
ME-26B/U
-----------------------------------------------
1
TM
11-6625-200-12
6625-542-6407
RF Wattmeter AN/URM-43A -----------------------------------------
1
TM
11-5133
6625-635-9186
6625-669-4031
Signal Generator AN/USM-44-----------------------------------------
1
TM
11-6625-508-10
-------------
RF Millivoltmeter Hewlett-Packard Model HP-411A ---------------------
1
-------------
P o w e r Supply, Trygon Model T20-2------------------------------------
2
b. Additional Equipment.
Federal stock No.
o
E n c l o s u r e , Electromagnetic, Shielding MX-1761/C ------------------------------------------
4940-542-0002
1
T o o l Kit, Radar and Radio Repairman TK-87/U --------------------------------------------
5180-690-4452
1
Test Assembly, consisting of: (See fig. 79.6 for fabrication details.)
-------------
Lamp, indicator, with push-to-test feature, 12 volts --------------------------------------
1
-------------
C o n n e c t o r , Methode Type No. SM-C-454687-------------------------------------------
1
Resistor, 150 ohms 5%, 1 watt, fixed, composition -------------------------------------
5905-683-2243
1
Resistor, 1,000 ohms 1%, 1 watt, fixed, composition ------------------------------------
1
5905-892-6330
Resistor, 10,000 ohms 5% variable, linear taper, composition ----------------------------
1
5905-892-6542
Resistor, 15,000 ohms 5%, 1 watt, fixed, composition -----------------------------------
1
5905-102-2824
5
TAGO 8344-A
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |