| MMS (Mast Mounted Site Simulators)
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The MMS is a component of the Air-to-Ground Engagement System II
Type: Ga:As
Wavelength: 904 nm
(AGES II) Simulator System.
Erbium Glass
1540 nm
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Laser Classification..............
This system lasers are considered Class 3a. They are considered safe if the operators are
informed of the hazards and use appropriate precautions.
Ocular injury .....................
Intentional viewing of the erbium glass laser is avoided due to normal glass absorption in
magnifying optics. Do not permit personnel to view the gallium-arsenide laser beam
within 260 m with unprotected optics. Optical systems which have a built-in (or added)
OD of 1.0 or greater at 904 nm will provide adequate protection at any viewing distance.
Other...............................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
REFERENCES: CHPPM Study 25-42-D1XC-94
MP Series Radio
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The MP Series is a 32 channel scanning portable VHF/UHF band transceiver. The
Frequency: 136 - 174 MHz (VHF)
unit utilizes a vertical dipole antenna.
403 430 MHz (UHF)
450 480 MHz (UHF)
Power: 5/1 W (VHF)
4/1 W (UHF)
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL) ....
This system is not able to produce potentially hazardous PDLs in excess of the safety
standard and is not subject to radiation protection control.
Hazard distance from antenna ....
Ensure personnel do not operate the radio with the antenna within 2.5 cm from the body.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Equipment - 202
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |