Click here to make tpub.com your Home Page

Page Title: Dark Invader Model 3020-I Night Vision System
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



Dark Invader Model 3020-I Night Vision System
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The 3020-I consists of a second-generation night vision image intensifying
Type: diode laser
Wavelength: 830 um
system combined with a 135 P/ 2.8 lens. The intended use of the device is
to observe persons engaged in simulated combat at night.
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Laser Classification..............
The CLD utilizes a Class 3b laser and requires an established laser safety program to
ensure its safe use. Develop a written Local Standing Operating Procedure (SOP) IAW
guidance provided in this TB.
Laser Hazard distance ..........
For extended viewing times, do not permit personnel to view the beam at distances less
than 60 m for unaided viewing and 700 m when viewing with magnifying optics.
For ten second viewing times, do not permit personnel to view the beam at distances less
than 30 m for unaided viewing and 400 m when viewing with magnifying optics. For
one second or less viewing times, do not permit personnel to view the beam at distances
less than 80 m for unaided viewing and 250 m when viewing with magnifying optics.
Outdoor range operations ......
When using the CLD, eliminate all specular surfaces (man made and natural) capable of
producing potentially hazardous reflections. Control unauthorized personnel access to
controlled area.
Other...............................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
DRAKE Model TR-7A Radio Set
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The TR-7A radio set is a commercially available system that utilizes
Frequency: 38 GHz
Power: 100 W
several antenna types; log-periodic, a vertical whip and doublet.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB) .
Hazard distance from antenna...
Exclude personnel to a distance of 0.3 m from the antenna.
Other................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Equipment - 183


Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business