BENDIX Model RDR 1206 (commercial)
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The RDR-1206 is an airborne weather radar set for fixed wing aircraft. It utilizes a
30 cm parabolic reflector dish antenna which is usually located on the nose of the aircraft.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
In the scanning mode, this system is not able to produce potentially hazardous PDLs in
excess of the safety standard. In the nonscanning mode, this system is able to produce
potentially hazardous PDLs in excess of the safety standard. Establish a Nonionizing
Radiation Protection Program (IAW guidelines provided in this TB) .
Hazard distance from antenna ....
In the nonscanning mode, exclude personnel to a distance of 2.0 m from the dish
antenna.
Other.................................
Consult the manufacturer's equipment Technical Manual for other operator and/or
maintenance hazards.
BENDIX Model RDR 1500
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The RDR-1500 is a continuous display airborne weather radar set for
Frequency: 9.375 GHz
Power: 4.7 W average
fixed wing aircraft. It utilizes a 46 cm diameter planar array antenna.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
In the scanning mode, this system is not able to produce potentially hazardous PDLs in
excess of the safety standard. In the nonscanning mode, this system is able to produce
potentially hazardous PDLs in excess of the safety standard. Establish a Nonionizing
Radiation Protection Program (IAW guidelines provided in this TB) .
Hazard distance from antenna ....
In the nonscanning mode, exclude personnel to a distance of 2.0 m from the antenna.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.