AN/VLQ-11 SHORTSTOP Electronic Protection System, Vehicle Group
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/VLQ-11 is an electronic countermeasures system
Frequency: CLASSIFIED
Power: CLASSIFIED
developed to protect personnel and equipment from incoming
artillery and mortar shells. This configuration consists of a core
receiver/transmitter (R/T) and an elevated spiral antenna
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL) ....
This system is not able to produce potentially hazardous PDLs in excess of the safety
standard and is not subject to radiation protection control.
RF shock/burn ......................
Observe standard RF shock precautions. Do not touch antenna when energized.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
AN/VPS-2A Radar Set
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/VPS-2 is a fire control radar set for the Vulcan
Frequency: 9.205 9.245 GHz
Power: 10.4 W average
Defense System. This set utilizes a 0.6 m diameter
parabolic reflector antenna.
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL)....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard.  Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB) .
Hazard distance from antenna...
Exclude personnel to a distance of 4.0 m in the direction of the main beam.
Open/cracked waveguides.......
All open waveguides and feed horn outputs produce potentially hazardous PDLs.
Exclude personnel from this area and do no permit operation of this system with any
cracked, broken or open waveguide.
Other................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Specify the use of dummy loads in maintenance operations. Instruct personnel not to
place eyes near the RF power indicator lamp located in the waveguide of earlier
systems.
REFERENCES: TM 9-1285-210-30