| AN/TRQ-33 Tactical Landing System
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/TRQ-33 is a tactical landing system which guides aircraft to a safe
Frequency: 15.412 15.688 GHz
landing strip. It transmits glideslope, centerline deviation, range and height
information to approaching aircraft. The system utilizes several antennas; a
Power:
2.0 kW PEP
pillbox-parabolic reflector (localizer); a pillbox-parabolic reflector
3.3 W av (localizer)
(glidescope); and a flared horn antenna (DME).
1.1 W av (glidescope)
3.3 W av (DME)
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB) .
Hazard distance from antenna ....
In the nonscanning mode, exclude personnel from within 1.5 m of the localizer antenna.
In the nonscanning mode, exclude personnel from within 0.5 m of the glidescope
antenna. In the nonscanning mode, exclude personnel from within 0.3 m of the DME
antenna.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
AN/TRQ-138 Radio Set
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AN/TRQ-138 is a radio set that operates in the
Frequency: 225 400 MHz
Power: 50 W
UHF\FLASHNET\Ionospheric modes and utilizes several antenna types.
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB) .
Hazard distance from antenna ....
Using the UHF communications antenna, exclude personnel from within 1.1 m of the
antenna. Using the FLASHNET antenna, exclude personnel from within 4.9 m of the
antenna. Using the ionospheric, exclude personnel from within 1.5 m of the antenna.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Equipment - 118
|