| AN/PVS-6 Mini-Eyesafe LASER Infrared Observation Set (MELIOS)
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AN/PVS-6 is a restricted eye-safe laser observation set primarily
Wavelength: 1540 nm
Type: Nd:YAG
used by infantry forward observers to accurately measure distance.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Laser Classification ............
This system contains a Class 3a laser and requires an established laser safety program to
ensure its safe use.
Hazard distance .................
Do not permit the MELIOS to be aimed at unprotected personnel using magnifying optics
within 18 m.
Ocular injury ....................
No eye protection is required for unaided viewing. The system is considered safe and
suitable for use during force-on-force exercises.
Other...............................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
REFERENCES: TM 111-5855-296-10; TM 11-5860-202-10