| AN/FSC-79A Satellite Communications Terminal (Modernized, Heavy Terminal)
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/FSC-79 is a satellite communications terminal that utilizes an
Frequency: 7.9 8.4 GHz
Power: 6300W max
18.3 m diameter parabolic dish antenna with a cassegrain feed and four
traveling-wave tube HPAs.
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in the main beam of the
antenna in excess of the safety standard. Establish a Nonionizing Radiation Protection
Program (IAW guidelines provided in this TB) .
Open/cracked waveguides .......
All open waveguides and loose or open flanges produce very hazardous PDLs within
close proximity of the break. Exclude personnel to within 4.2 m from a fully open
guide at the transmitter. (The system uses a pressurized waveguide interlocked with the
transmitter to prevent operation without adequate guide pressure).
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
REFERENCES: TM 11-5895-358-14
AN/FSQ-84 Radar System
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/FSQ-84 is a radar system designed to provide high resolution
Frequency: 9.0 9.16 GHz
Power: 180 W
aircraft identification. This system consists of the AN/FPN-40 Ground
Control Approach radar configured with the AN/TPX-41 Interrogator
Set. This system utilizes two prime-fed parabolic antennas (azimuth
and elevation).
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
In the nonscanning mode, this system is able to produce potentially hazardous PDLs in
the main beam of the antenna in excess of the safety standard. Establish a Nonionizing
Radiation Protection Program (IAW guidelines provided in this TB) . Follow hazard
criteria for the AN/FPN-40 and AN/TPX-41. Prohibit directing either non-scanning
main beam of the AN/FPN-40 antennas to the AN/TPX-41 shelter.
Hazard distance from antenna ....
When operating in the non-scanning mode, limit ground personnel to a distance of
24.4 m along the main beam of the elevation antenna.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance
hazards. Instruct personnel not to use the "Switch Viewing" window while the
transmitter is on.