AN/ARN-124 Distance Measuring Equipment (DME)
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AN/ARN-124 is an airborne tranceiver set that utilizes
Frequency: 0.96 1.2 GHz
Power: 25 mW average;
the AT-741 antenna.
PEP 500 W
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
This system is not subject to radiation protection control.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
REFERENCES: TM 11-5826-300-20
AN/ARQ-31 Radio Receiving Set
SYSTEM DESCRIPTION
SYSTEM PARAMETERS
The AN/ARQ-31 is the airborne radar set of the Tactical Landing
Frequency: 15.2 GHz
Power: 2 W average
System. It utilizes a slotted cylinder antenna.
HAZARD CONTROLS (to reduce or eliminate risk)
SYSTEM HAZARDS
Power Density Levels (PDL) ....
This system is able to produce potentially hazardous PDLs in excess of the safety
standard. Establish a Nonionizing Radiation Protection Program (IAW guidelines
provided in this TB) .
Hazard distance from antenna ....
Exclude personnel to a distance of 6 cm from the antenna aperture.
Other.................................
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Equipment - 25