| AH-1S Laser Rangefinder/Illuminator
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AH-1S is a helicopter-mounted laser rangefinder designator mounted on
Type: Nd-YAG
Wavelength: 1064 nm
the nose of the aircraft.
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Laser Classification ............
This system contains a Class 4 laser and requires an established laser safety program to
ensure its safe use. Develop a written Local Standing Operating Procedure (SOP) IAW
guidelines provided in this TB.
Hazard distance .................
Do not permit personnel to view the laser from within the beam at distances less than 6.3
km for unaided viewing, or 40 km when viewing the laser through magnifying optical
instruments.
Ocular injury ....................
Use protective eyewear that filter at 1064 nm with a minimum OD of 3.8 for unaided
viewing, and a minimum OD of 4.5 for viewing through magnifying optical instruments.
Eliminate all specular surfaces (man made and natural) capable of producing potentially
Outdoor range operations .....
hazardous reflections. Control unauthorized personnel access to controlled area. Appoint a
qualified Laser Range Safety Officer.
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Other...............................
AIM-1/D Laser Aiming Device
SYSTEM PARAMETERS
SYSTEM DESCRIPTION
The AIM-1/D is a battery powered IR laser aiming device which can be fitted on a variety of
Type: Gallium-Al:Arsenide
weapons. The system has two modes, local and remote, with a high and low intensity
Wavelength: 800 - 850 nm
setting.
SYSTEM HAZARDS
HAZARD CONTROLS (to reduce or eliminate risk)
Laser Classification ............
This system contains a Class 3b laser and requires an established laser safety program to
ensure its safe use. Develop a written Local Standing Operating Procedure (SOP). This
laser, when used with its training filter, is a Class 1 laser device.
Hazard distance .................
When not using the training filter, do not permit the user to aim at unprotected personnel
within 236 m or at personnel using magnifying optics within 3.55 km.
Ocular injury ....................
Use protective eyewear that filter at 830 nm with a minimum OD of 2.5 for unaided and
aided viewing.
Consult the equipment Technical Manual for other operator and/or maintenance hazards.
Other...............................
Do not operate the AIM-1/D without the training filter covering the exit port.
Equipment - 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |